HFS-DC1
Column Tension and Compression Load Cell
Column and S-type load-cell configurations with threaded force connections for industrial force and weighing inspection.
- Selected capacity range
- 50 kg–20 t
- Technical-reference capacity range
- 50 kg–100 t
- Selected accuracy
- ±0.5%
Supplied by WKSENSOR. Ask us about pricing, availability and delivery.
Product overview
Two pictured sensing-body forms
Column and S-type structures for tension and compression measurement in force and weighing inspection equipment.
Capacity and connection threads
| Technical-reference capacity | Connection thread |
|---|---|
| 50–700 kg | M16 × 1.5 |
| 1–5 t | M24 × 1.5 |
| 8–10 t | M36 × 4 |
| 20 t | M36 × 4 |
| 30 t | M45 × 4.5 |
| 50 t | M64 × 3 |
| 100 t | M76 × 3 |
Body dimensions by reference capacity
The drawing distinguishes 50 kg–10 t bodies from the 20–100 t section. ØB and W are supplied only for some smaller versions. H2 identifies the threaded depth; H1 is drawn but not quantified in the matrix. Dimensional units require confirmation. Confirm the body dimensions and usable thread depth for your selected capacity before designing the connection. A dash means the dimension is unavailable here and must be confirmed for the selected version.
50–700 kg
- ØA / ØB / W
- Ø44 / Ø28 / 26
- H / H2
- 88 / 18
1–5 t
- ØA / ØB / W
- Ø58 / Ø38 / 44
- H / H2
- 112 / 24
8–10 t
- ØA / ØB / W
- Ø84 / Ø60 / —
- H / H2
- 160 / 36
20 t
- ØA / ØB / W
- Ø60 / — / —
- H / H2
- 180 / 40
30 t
- ØA / ØB / W
- Ø76 / — / —
- H / H2
- 213 / 50
50 t
- ØA / ØB / W
- Ø94 / — / —
- H / H2
- 332 / 70
100 t
- ØA / ØB / W
- Ø112 / — / —
- H / H2
- 367 / 80
Configuration and selection
- Capacity
- The selected capacity range is 50 kg–20 t. The dimensional table covers 50 kg–100 t with capacity-specific connection threads; confirm the required capacity and thread combination.
- Material and protection
- Alloy-steel or stainless-steel material options, with IP65 and IP66 versions available.
- Electrical reference
- Analogue-voltage output; bridge specifications are 2.0 ±0.05 mV/V sensitivity and 5–12 V excitation.
Technical reference
Specifications and options
| Parameter | Specification or option |
|---|---|
| Model | HFS-DC1 |
| Selected capacity range | 50 kg–20 t |
| Technical-reference capacity range | 50 kg–100 t |
| Force measurement | Tension and compression |
| Selected output | Analogue voltage |
| Selected accuracy | ±0.5% |
| Technical-reference sensitivity | 2.0 ±0.05 mV/V |
| Nonlinearity | ±(0.05–0.1)% FS |
| Hysteresis error | ±(0.05–0.1)% FS |
| Repeatability error | ±0.05% FS |
| Creep | ±0.05% FS |
| Zero temperature coefficient | ±0.05% FS/10°C |
| Sensitivity temperature coefficient | ±0.05% FS/10°C |
| Input resistance | 380 ±30 Ω |
| Output resistance | 350 ±5 Ω |
| Operating temperature | −20–70°C |
| Safe overload | 150% FS |
| Insulation resistance | ≥2000 MΩ |
| Excitation voltage | 5–12 V |
| Protection versions | IP65 / IP66 |
| Material options | Alloy steel / stainless steel |
| Cable length | 3 m |
| Brand | WKSENSOR |
| Product reference | HH-759204850071 |
Application scenarios
Applications include force and weighing inspection in industrial automation. Other applications include robots, injection moulding, automotive manufacturing, water conservancy, batching and hoisting.
Batching and weighing
Industrial batching and weighing-inspection applications.