HFS-CS2
Miniature Tension and Compression Load Cell
A compact diaphragm load cell for tension, compression and weighing tests, with opposed threaded studs and rated-load configurations from 50 kg to 2 t.
- Accuracy options
- 0.5% FS / 0.2% FS / 0.1% FS
- Reference nonlinearity
- ±0.3%–±0.5% FS
- Output resistance
- 700 ±5 Ω
Supplied by WKSENSOR. Ask us about pricing, availability and delivery.
Product overview
Opposed threaded load connections
Threaded studs extend from both ends of the cylindrical body. Socket-head fasteners surround the raised upper centre, and a side fitting carries the short black cable.
The compact body is intended for medical equipment and industrial force and weighing test systems.
- Bidirectional force measurement
- The flat-diaphragm sensing structure accepts tension and compression loads.
- Compact threaded assembly
- The reference drawing identifies M12 connections at both ends.
Dual-stud installation dimensions
| Body diameter | Ø50 |
|---|---|
| Overall height | 70 |
| Central body segment | 27 |
| Upper stack / stud | 19 / 18 |
| Lower stack / stud | 24 / 16 |
| Cable fitting projection | 14 |
| Lower reference diameter | Ø26 |
| Load connections | M12, both ends |
Dimensional units and M12 thread pitch require confirmation.
Configuration and selection
- Rated load
- Capacity configurations from 50 kg to 2 t.
- Bridge signal
- Selected nominal sensitivity: 2.0 mV/V. Other sensitivity configurations are 1.5–2.0 ±0.05 mV/V with 5–12 V excitation; confirm the required combination.
- Accuracy option
- Accuracy options: 0.5% FS, 0.2% FS or 0.1% FS.
- Load connections
- M12 threaded studs at both ends.
- Material
- Alloy-steel or stainless-steel configurations.
Technical reference
Specifications and options
| Parameter | Specification or option |
|---|---|
| Model | HFS-CS2 |
| Rated-load configurations | 50 kg–2 t |
| Selected nominal sensitivity | 2.0 mV/V |
| Reference sensitivity | 1.5–2.0 ±0.05 mV/V |
| Accuracy options | 0.5% FS / 0.2% FS / 0.1% FS |
| Reference nonlinearity | ±0.3%–±0.5% FS |
| Hysteresis error | ±0.3% FS |
| Repeatability error | ±0.3% FS |
| Reference creep | ±0.1% FS |
| Zero temperature coefficient | ±0.1% FS / 10 °C |
| Sensitivity temperature coefficient | ±0.1% FS / 10 °C |
| Input resistance | 750 ±30 Ω |
| Output resistance | 700 ±5 Ω |
| Operating temperature | −20–70 °C |
| Safe overload | 150% FS |
| Insulation resistance | ≥2000 MΩ |
| Excitation voltage | 5–12 V |
| Protection | IP66 |
| Material options | Alloy steel / stainless steel |
| Connection thread | M12 |
| Reference cable length | 3 m |
| Long-term stability | ≤0.2% FS / year |
| Brand | WKSENSOR |
| Product reference | HH-759212898067 |
Application scenarios
The HFS-CS2 is used in medical equipment and industrial force and weighing tests. Applications also include robotics, injection moulding, automotive manufacturing, water conservancy, batching and lifting.
Batching and weighing
Industrial force and weighing applications.