HVAC & cleanrooms

Air differential pressure, duct temperature and humidity, and room-condition measurement for ventilation and building systems.

Room pressure and air conditions are measured at different locations. A differential-pressure transmitter connects to two air-pressure points; a duct probe measures inside the air stream, while a wall-mounted transmitter measures room air.

Outdoor air-conditioning units with ventilation grilles and connecting service pipes
HPT-8 low differential pressure transmitter with two pressure ports

Air pressure

Room and ventilation pressure differences

The HPT-8 measures low differential pressure in gas applications. Its two pressure ports connect to the air-pressure points being compared. Display and non-display configurations are available for ventilation and room-pressure measurement.

HPT-8Low differential pressure transmitter

Connection
Two gas-pressure ports
Signal options
4–20 mA, 0–10 V or RS485
View HPT-8 specifications
SBW-19 enclosure with an extended duct temperature and humidity probe

Duct conditions

Temperature and humidity in the air stream

The SBW-19 uses an extended vented probe to measure air temperature and relative humidity inside a duct. The enclosure stays outside the duct, with display and plain-front versions available. The probe is intended for air measurement.

SBW-19Duct temperature and humidity transmitter

Humidity range
0–100% RH
Signal options
4–20 mA, voltage or RS485
View SBW-19 specifications
SBW-17 wall-mounted enclosure with temperature and humidity display

Room conditions

Wall-mounted temperature and humidity

The SBW-17 measures air temperature and relative humidity with a local dual-reading display. Wall mounting suits monitored rooms and equipment spaces where the reading needs to remain visible at the measuring point.

SBW-17Wall-mount temperature and humidity transmitter

Temperature spans
0–50 °C or −20–80 °C version
Supply
12–36 V DC; nominal 24 V DC
View SBW-17 specifications

Configuration for your application

Measuring location

Identify the two air-pressure points, duct insertion location or room-air position for each instrument.

Span and indication

Choose the differential-pressure or temperature span and whether local indication is needed.

Building-system interface

Select the current, voltage or RS485 version to match the building-system input and available power supply.